Availability: | |
---|---|
Quantity: | |
Description
ASP5010 series chemical pump is single stage single suction cantilever centrifugal pump,which is designed by national standard ISO2858/ISO5199 with design theory that is scientific and reasonable,standardized and modularized to make sure the product operates steadily,economically and high efficiently and energy saving.
Pump standard fits ISO、API、GB、ASTM、JIS,and the material of wet parts can be chosen according to different transmitted medium.
Power supply that is 50Hz and 60Hz can be applied to ASP5010 series chemical pump.
Application Area
Power plant、steel and metal manufacturing、chemical plant、refinery、food industry、automobile industry、waste incineration plant、seawater desalting plant etc.
Performance Range
Outlet diameter: 25-200mm
Capacity: Up to 1500m3/h
Head: Up to 125m
Working pressure: The highest 2.5MPa
Temperature: The highest 160℃
Structural Characteristics
1、Pump is designed by horizontal installation single stage cantilever.
2、Two angular contact bearings and one cylindrical roller bearing are applied on the bearing box,which can bear the radial force and axial force of pump efficiently.
3、Pulling part of bearing box is whole-back-pulling type.So there is no need to dismantle the outlet and inlet pipeline of pump at site,which shall be convenient for the maintenance of pump at site.
4、There is empty chamber in the pump cover to keep warm and to cool,which is suitable for the medium that needs to be kept warm or cooled.
5、Type of impeller includes closed impeller and open impeller.Closed impeller is used to transmit common medium,and open impeller is used to transmit corrosive liquid and liquid that can be easily crystallized or liquid that contains gas.
6、GB9115.2-2000 is applied on flange standard,dimension standard of outlet flange and inlet flange,which is equal to HG20592-97.
7、Wire thread is applied on the impeller nut to prevent it from loosening due to the vibration during pump operation or reverse.
8、Pump rotates clockwise,from the direction of driver end.
9、Shaft seal
Seal chamber is designed according to API682 standard.And balancing-type single mechanical seal is taken as standard.Double mechanical seal or tandem type mechanical seal can be applied according to the requirements of user. Cartridge seal is wholly installed in the seal chamber,which makes the maintenance of sealing parts quick and convenient without being dismantled.Shaft seal can also be made into packing seal as the requirements of clients.
Model significance
Sectional Drawing
Range Coverage Chart
Description
ASP5010 series chemical pump is single stage single suction cantilever centrifugal pump,which is designed by national standard ISO2858/ISO5199 with design theory that is scientific and reasonable,standardized and modularized to make sure the product operates steadily,economically and high efficiently and energy saving.
Pump standard fits ISO、API、GB、ASTM、JIS,and the material of wet parts can be chosen according to different transmitted medium.
Power supply that is 50Hz and 60Hz can be applied to ASP5010 series chemical pump.
Application Area
Power plant、steel and metal manufacturing、chemical plant、refinery、food industry、automobile industry、waste incineration plant、seawater desalting plant etc.
Performance Range
Outlet diameter: 25-200mm
Capacity: Up to 1500m3/h
Head: Up to 125m
Working pressure: The highest 2.5MPa
Temperature: The highest 160℃
Structural Characteristics
1、Pump is designed by horizontal installation single stage cantilever.
2、Two angular contact bearings and one cylindrical roller bearing are applied on the bearing box,which can bear the radial force and axial force of pump efficiently.
3、Pulling part of bearing box is whole-back-pulling type.So there is no need to dismantle the outlet and inlet pipeline of pump at site,which shall be convenient for the maintenance of pump at site.
4、There is empty chamber in the pump cover to keep warm and to cool,which is suitable for the medium that needs to be kept warm or cooled.
5、Type of impeller includes closed impeller and open impeller.Closed impeller is used to transmit common medium,and open impeller is used to transmit corrosive liquid and liquid that can be easily crystallized or liquid that contains gas.
6、GB9115.2-2000 is applied on flange standard,dimension standard of outlet flange and inlet flange,which is equal to HG20592-97.
7、Wire thread is applied on the impeller nut to prevent it from loosening due to the vibration during pump operation or reverse.
8、Pump rotates clockwise,from the direction of driver end.
9、Shaft seal
Seal chamber is designed according to API682 standard.And balancing-type single mechanical seal is taken as standard.Double mechanical seal or tandem type mechanical seal can be applied according to the requirements of user. Cartridge seal is wholly installed in the seal chamber,which makes the maintenance of sealing parts quick and convenient without being dismantled.Shaft seal can also be made into packing seal as the requirements of clients.
Model significance
Sectional Drawing
Range Coverage Chart